Flame detector x5200 manual






















In typical applications, the four wire X can use all existing system wiring. The evolution continues with the new X UVIR Flame Detector. The X meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design.  · The X UVIR Flame Detector meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The mounting arrangement allows the UV and IR sensors to monitor the same hazardous location with a 90 degree cone of vision. UVIR detector for complex detection environments. The X UVIR hydrocarbon flame detector can be configured to satisfy third-party requirements for rapid detection or for applications where extraneous IR radiation sources may cause other detectors to generate .


X UV/IR Flame Detector. The X UVIR flame detector can be configured to satisfy third-party requirements for rapid detection or for applications where extraneous IR radiation sources may cause other detectors to generate false alarms. This detector can operate in combination mode as a UVIR or in a single mode as a UV or IR. detectors. laser aimer: cone of vision tester for sighting and testing the area of coverage of the detector. air shields for reduced maintenance in areas where there is an abnormally high level of airborne contaminants. test lamps to test the system without using an open flame are available for detectors without manual or mag oi. This guide instructs gas detection personnel on the features and usage of the PS Portable Gas Monitor (or "the monitor"), including information on operation, configuration, maintenance, specifications and troubleshooting. This user guide assumes the reader has a basic knowledge of gas detection procedures. Guide Conventions.


X UVIR Flame Detector. manual or magnetic optical. X UVIR Flame Detector. Supplied by Det-Tronics. Approved to FM (), the X meets the most stringent requirements worldwide with advanced detection. X Uvir Flame Detector Manual. Safety manual X UV, X IR, X uvir SIL 2. Automatic, manual or magnetic optical integrity (oi) testing, no external test. the recommendations in this manual may impair system performance and compromise safety. ATTENTION The X, XG, and XM include the Automatic oi® (Optical Integrity) feature — a calibrated performance test that is automatically performed once per minute to verify complete detector operation capabilities. Testing with an. NOTE: Refer to the X instruction manual (form number ) for details regarding detector response. Fuel Size Distance Typical Response Time Feet (M) (Seconds) n-Heptane 1 x 1 foot 85 () 14 Methane 32 inch plume 65 () 5 Detector Electronics Corporation West th Street • Minneapolis, Minnesota USA.

0コメント

  • 1000 / 1000